Welcome to the company ! we have many years of professional experience !
rsdzd@pyzyrsd.com +86 513525609655

gas testing waste water up-to-standard emission treatment centers locations

Established in 2001, Puyang Zhong Yuan Restar Petroleum Equipment Co.,Ltd, “RSD” for short, is Henan’s high-tech enterprise with intellectual property advantages and independent legal person qualification. With registered capital of RMB 50 million, the Company has two subsidiaries-Henan Restar Separation Equipment Technology Co., Ltd We are mainly specialized in R&D, production and service of various intelligent separation and control systems in oil&gas drilling,engineering environmental protection and mining industries.We always take the lead in Chinese market shares of drilling fluid shale shaker for many years. Our products have been exported more than 20 countries and always extensively praised by customers. We are Class I network supplier of Sinopec,CNPC and CNOOC and registered supplier of ONGC, OIL India,KOC. High quality and international standard products make us gain many Large-scale drilling fluids recycling systems for Saudi Aramco and Gazprom projects.

Certificate of Honor

Get in touch with us

We will confidentially process your data and will not pass it on to a third party.

gas testing waste water up-to-standard emission treatment centers locations
SOLUTION FOR WASTEWATER PROBLEM RELATED TO ELECTROPLATING …
SOLUTION FOR WASTEWATER PROBLEM RELATED TO ELECTROPLATING …

In the last decades the most talked advances in the treatment of wastewater has been the use of ozone. The use of ozone is becoming more popular in wastewater treatment. The development in technology of producing ozone acidic behaviour of the solution generates the dangerous hydrogen cyanide gas that creates air pollution problem.

Electroplating Wastewater Treatment_Method
Electroplating Wastewater Treatment_Method

Deplate wastewater Ask a professional and qualified environmental company to handle it. The wastewater treatment process is also used by most electroplating companies. It is quite representative. In practice, there are many difficulties that have caused most of the electroplating factories' wastewater treatment to fail to meet the standards.

Heavy Metal Complexes Wastewater Treatment with Chelation ...
Heavy Metal Complexes Wastewater Treatment with Chelation ...

Because chelator can be used directly to treat ,acidic wastewater, containing heavy metals, it is unnecessary to destroy the constitution of metal complexes preliminarily, and therefore the cost for pH adjustment can be saved and the ,treatment, process can be simplified.

Treatment of Electroplating Waste -- Student Project
Treatment of Electroplating Waste -- Student Project

However, if not possible, one potential ,treatment, strategy is bringing the pH of the waste low, then adding an iron salt to try to get the gluconate to mostly tie up iron rather than copper, then raising the pH with lime. This strategy is sometimes called "chelate breaking" in the ,wastewater treatment, industry. Regards, Ted Mooney, P.E.

METHOD FOR INTEGRATED TREATMENT OF ELECTROPLATING ...
METHOD FOR INTEGRATED TREATMENT OF ELECTROPLATING ...

A method for integrated ,treatment, of ,electroplating wastewater,, comprising: (1a) adjusting the ,electroplating wastewater, with lime milk to pH of 10.5-12 under mechanical stirring, and adding an oxidant for an oxidation for 90-240 minutes by controlling an ORP value to precipitate pyrophosphate, phosphate, heavy metal ions and fluoride ions; (2a) adding a ferrous chloride solution into the ...

Printing - Standard Methods for the Examination of Water ...
Printing - Standard Methods for the Examination of Water ...

200-,mL,, tall-form Berzelius beaker without a spout. Fit beaker with a stopper having three holes, to accommodate the two electrodes and the buret. With a miniature combination glass-reference electrode use a 125-,mL, or 250-,mL, erlenmeyer flask with a two-hole stopper. c. Magnetic stirrer. d. Pipets, volumetric. e. Flasks, volumetric, 1000-, 200 ...

Electrochemical Treatment of Electroplating Wastewater ...
Electrochemical Treatment of Electroplating Wastewater ...

-The electrodes were cleaned by grinding and polishing followed by immersing in, 10% hydrochloric acid, and, rinsing, in, tap water, prior to every run then dipped in the synthetic electroplating wastewater. -The electroplating wastewater effluent concentration was maintained during each experment.

Removing Heavy Metals from Wastewater | Products Finishing
Removing Heavy Metals from Wastewater | Products Finishing

The removal of soluble heavy metal ions from ,wastewater, is a common industrial treatment ... The zinc/nickel of choice for today’s surface finishing industry is an alkaline electrolyte chemistry instead of an ,acid, electrolyte ... lead carbonate is essentially insoluble (0.00011 g/,100 mL, at 20°C) and will precipitate out ...

Treatment system and process for treating acidic copper ...
Treatment system and process for treating acidic copper ...

The invention discloses a ,treatment, system for treating ,acidic, copper-containing ,electroplating wastewater,. The ,treatment, system comprises a ,wastewater, collecting unit, a pre-,treatment, unit, an ultra-filtration unit, a concentration unit and a reverse osmosis unit which are sequentially communicated by a pipeline, wherein the ,wastewater, collecting unit comprises a ,wastewater, collecting barrel ...

(PDF) Treatment of Electroplating Wastewater Using NF pH ...
(PDF) Treatment of Electroplating Wastewater Using NF pH ...

Industrial adoption of, nanofiltration, (NF) for treatment of, low-pH wastewater, is hindered by the limited membrane lifetime at strongly acidic conditions. In this study, the electroplating...

Electroplating wastewater treatment - chemical methods ...
Electroplating wastewater treatment - chemical methods ...

Electroplating wastewater. Wastewater, from, electroplating, and printing plates is classified as, acidic, or alkaline metal containing, wastewater., Therefore the treatment includes methods that neutralize, acids, and alkali, extract metals, but do not extract organic contaminants. As a result, there is a difficulty to extract metal organic complexes. It should also be noted that certain organic impurities in the, electroplating wastewater, …

SOLUTION FOR WASTEWATER PROBLEM RELATED TO …
SOLUTION FOR WASTEWATER PROBLEM RELATED TO …

In the last decades the most talked advances in the treatment of ,wastewater, has been the use of ozone. The use of ozone is becoming more popular in ,wastewater, treatment. The development in technology of producing ozone ,acidic, behaviour of the solution generates the dangerous hydrogen cyanide gas that creates air pollution problem.

Treatment of Electroplating Waste -- Student Project
Treatment of Electroplating Waste -- Student Project

2000. A. Anusha: Some good books available on the treatment ,of electroplating, waste include: "Operation and Maintenance of Surface ,Finishing Wastewater, Treatment Systems" [affil. link to book on Amazon] and Water and Waste Control For the Plating Shop".For a much briefer treatment of the subject, there is coverage in the Metal ,Finishing, Guidebook, the "Products ,Finishing," Directory, and the ...

Standard Methods for the Examination of Water and Wastewater
Standard Methods for the Examination of Water and Wastewater

As the end point is approached make smaller additions of ,acid, and be sure that ,pH, equilibrium is reached before adding more titrant.d. Potentiometric titration of low alkalinity: For alkalinities less than 20 mg/L titrate ,100, to 200 ,mL, according to the procedure of ¶ 4c, above, using a 10-,mL, microburet and 0.02N standard ,acid, solution.

Electroplating Wastewater Treatment_Method
Electroplating Wastewater Treatment_Method

Deplate ,wastewater, Ask a professional and qualified environmental company to handle it. The ,wastewater, treatment process is also used by most ,electroplating, companies. It is quite representative. In practice, there are many difficulties that have caused most of the ,electroplating, factories' ,wastewater, treatment to fail to meet the standards.

Improving efficiency of electroplating wastewater treatment
Improving efficiency of electroplating wastewater treatment

The traditional approaches to electroplating wastewater treatment involve chemical, reagent,, electrochemical and ion exchange methods, as well as adsorption treatment. The reagent method is one of the simplest and most common methods.

Liquid waste treatment in galvanizing and zinc electroplating
Liquid waste treatment in galvanizing and zinc electroplating

2/4/2019, · The wastewater treatment process goes from, removal, of heavy metals to treatment of the, emulsion, and, neutralization, of effluents. This produces wastewater with a high content of calcium, sodium, sulphates, chlorides, mainly from the processes of neutralization and electrolyte use. These high salinity parameters require specific treatments.

Laboratory Procedures: Analysis for Wastewater Treatment ...
Laboratory Procedures: Analysis for Wastewater Treatment ...

P " ,ml, of 0.02N sulfuric ,acid, used for the titration to ,pH, 8.3 T » ,ml, of ,acid, used for total titration (above ,pH, 8.3 plus ,acid, used to 4,5) There are five possible conditions: 1. P - …

Treatment of Electroplating Wastewater by Adsorption Technique
Treatment of Electroplating Wastewater by Adsorption Technique

Abstract—The wastewater treatment process was evaluated in an, Electroplating, unit that practiced chrome and bronze, plating., With a view to recycle and reuse the wastewater, adsorption process was adopted as single stage treatment instead of the existing chemical methods. Wastewater was collected from chrome and bronze plating

Treatment of electroplating wastewater using the freezing ...
Treatment of electroplating wastewater using the freezing ...

1/3/2020, · When, electroplating washing wastewater, is treated by the SWDIM freezing method: (1) after primary freezing, treatment, and centrifugal dehydration, about 0.62 of the volume of the original wastewater is purified and can be reused in the primary washing tank; (2) after secondary freezing and centrifugal dehydration, the concentrated wastewater of about 0.14 vol of the original wastewater can …

Chat Online Inquiry Email

Business cooperation

+86 513525609655

Company address

Road West, North Branch, Jingkai Road, Puyang City